Get a Quote

Glycol - Industrial Water Chilling

70% Water. -15C / 5F Freeze Protection **. -29C / -20F Burst Protection. Outdoor Chiller / Low Temperature System: 50% Glycol. 50% Water. -37C / -35F Freeze Protection **. -51C / -60F Burst Protection. Contact us to purchase 55 gallon drums, or …

Vilax Pune - Manufacturer of Industrial Chiller and Panel ...

About Us. “Vilax” is a well-known Manufacturer of a trendy and flawless assortment of Oil Chiller, Water Chiler, Oil Chillers, etc. Incepted in the year 2020 at Pune (Maharashtra, India), we design these apparels as per current market trends. We are a Proprietor company, which is actively committed to providing high-quality products.

Water Chiller Air-cooled and Water Cooled Ultimate Guide

Brand Pressure Controller, Filter Drier to Ensure the Reliability of the Industrial Water Chiller Unit. Cooling Capacity Ranges: 30 Ton~4500 Ton. Coolant Temperature from -140℃~30℃. Adopts Famous Bitzer Compressor, Hanbell Compressor, Fusheng Compressor; Compressor Energy Efficiency is 20%~30% Higher;

Industrial chiller Plating machine

Built-in 304 stainless steel water tank insulation, stainless steel horizontal pipes circulating pump, which is effectively ensure the cleanliness of the water quality. Inside industrial chiller machine selection of efficient large diameter, large temperature difference hydrophilic aluminum foil by precision machining process is completed ...

Top Ten Proper Chiller Maintenance Tips

Clean air filters, blow and/or wash out. Check water quality/glycol mixture. Inspect fluid filters/strainers. Inspect fluid system for. Fluid leaks. Loose pipe fittings or hoses. Plumbing parts for wearing, cracking or chafing. Check voltage and amp draw. Readings should be within +/- 10% of the nameplate.

Maintenance Is Critical To Maintain Chiller Performance ...

Feb 04, 2022 Since it doesn’t require a whole lot of fouling or scale buildup to cause problems, you should keep a close on water treatment and chemistry. Review Your Refrigerant. Another critical aspect of chiller maintenance is to keep an eye on refrigerant levels, making sure they stay within the manufacturer’s recommended levels.

High Quality Chiller Manufacturer and Supplier in China ...

In industrial application, chilled water from the chiller is used to control the product at a proper temperature and cool the industrial machine or process. High-quality chiller made by TopChiller features a compact design, high cooling performance, energy efficiency, easy operation, and low maintenance, which have been exported to more than 58 ...

Home HVAC Services Maintenance Chiller annual ...

Increase Chiller’s Efficiency with Tube Inspection. Leaving temperature differing (LTD) analysis improves chiller performance and efficiency through checking tube cleaning time and providing customer water quality management guide. Note) LTD (Cond.) = Cond. Ref. Temp. – Cooling Water Outlet Temperature.

Seasonal Maintenance Tips - North Slope Chillers

Inspect and clean the chiller condenser, which removes the heat transferred into the refrigerant by the compressor. Heat transfer can take its toll on chiller systems and is important to producing efficient chiller operation. Routine maintenance should inspect the following: Air intake and exhaust temperature.

Maintenance Method of Condenser in Water Chiller Units ...

Its cleaning cycle is generally based on water quality. If the water quality is poor, it should be cleaned at least once a year. If the water quality is good, such as pure water, it can be cleaned once every 2 to 3 years. Perhaps some of the chillers use …

Chiller Maintenance During the Winter - Plant Equipment ...

Jan 18, 2016 We probably already work for your chill water maintenance provider, Carrier, JCI-York, Daikin-Mcquay, Trane and others. Plant Equipment Services uses the highest quality of products and offers the best service and warranties compared to anyone else in the industry. Due to new developments in centrifugal chillers with magnetic bearing chillers ...

Chiller - Lab Instrument Manufacturer

Jul 09, 2021 Sufficient fresh make-up air allows for the maintenance of a suitable temperature within the space. Water-cooled chillers do not require ventilation or fresh make-up air. ... additional costs may accrue from the regular monitoring of water quality, treatment of the water, and the operation of fans and pumps. ... Industrial water chiller system ...

Good Water Treatment Program Improves Chiller Efficiency ...

Jul 18, 2013 One of the simplest yet most often overlooked elements in chiller maintenance programs is the operating log. A typical chiller operating log includes regularly recorded data that tracks chiller performance, condenser-water supply and return temperatures, chilled-water supply and return temperatures, evaporator and condenser pressures, oil temperature and …

Chiller Maintenance - Galgon HVAC

Jul 28, 2020 7. Analyze compressor oil. Most chiller manufactures recommend sending a sample of the oil in the chiller to be analyzed by a lab once a year depending on the chiller and maintenance schedule. Like any hermetically sealed refrigeration system, the oil should only be replaced if the analysis indicates it’s needed.

How to clean a water chiller

Jun 05, 2021 We have to distinguish between water-cooled and air-cooled. The water-cooled chiller is mainly used to remove the scale of the chiller. The removal cycle depends on the water quality. If the water quality is poor, it is cleaned at least once every 12 months; if the water quality is good, it can be cleaned once every 2 years on average.

Chilled Water Quality AMP Maintenance Forums

Jun 19, 2010 The main components in the system are: Heat Exchanger Tubes made of copper. Circulating pumps made of cast iron. All pipework made of Stainless Steel 304. Evaporator at chiller made of copper tubes, cast iron end covers and the body I suspect being steel. The water fed to fill the system is of pH 6.5 and conductivity of around 120microSiemens.

Monitoring Cooling Water Flow for Efficient Industrial ...

Jun 21, 2021 Cooling water systems are often used in commercial and industrial buildings. They are used in these industries to remove waste heat from the cooling process of HVAC systems. Monitoring the cooling water flow is essential in any structure that needs cooling. Any change in the cooling water flow will affect the overall performance of HVAC systems.

Notes For Installation And Maintenance Of SCY Chiller ...

Jun 25, 2021 Notes for Installation and maintenance of SCY Chiller. ... If the unit is installed in an area with poor water quality, water treatment should be carried out to avoid damage to the heat exchanger. ... SCY Chiller is a professional manufacturer of industrial chiller, air-cooled chiller, water-cooled chiller, glycol chiller from China. +86 ...

Water Chilling System Industrial Water Chiller ...

Key Features. Chiller cooling capacity: 0.5 Ton to 50 Ton. Chiller temperature control range from -40℃to 30℃. Hanbell/Bitzer semi-hermetic screw compressor. Copeland/Panasonic hermetic scroll compressor. Air cooled chiller and water cooled chiller available. Chiller features energy and cost saving with a compact design.

Cooling water quality - Lenntech

LennRO Industrial Reverse Osmosis; Industrial Microfiltration; HPNow Peroxide Generators; Request a quote; Phone: +31 152 610 900 ... Maintenance; Rental Units; Troubleshooting; ... Cooling water quality. Cooling water quality depends on the type of heat exchanger or engine to be cooled. Very generally, it should have the following quality:

Ten Tips for Commercial Chiller Maintenance Contracting ...

Mar 01, 2010 Keep chilled water flow rate between 3 to 12-ft per second Changing the chilled water flow rate affects a chiller's performance. Too low a flow rate lowers the chiller efficiency and ultimately leads to laminar flow. The minimum flow rate is typically around 3-ft. per second (FPS). Too high a flow rate leads to vibration, noise, and tube erosion.

How to use the chiller simply and correctly

Mar 10, 2022 9. Regularly check whether the quality of the chilled water and cooling water is normal. When the water quality of the water source becomes dirty or degenerated, please replace the water source in time. Two: The annual maintenance of the chiller is as follows: 1. Clean the condenser (every six months of cumulative operation) 2.

Air Cooled Chiller Maintenance - LEL

Mar 28, 2016 Keeping the water supply clear of these scales and deposits adds years to the potential life of service of these vulnerable components. Chiller manufacturers advise testing water quality and cleaning, if necessary, once every few months. REFRIGERANT LEVEL AND QUALITY. Two main problems can occur in relation to an air cooled chiller’s refrigerant.

Methods Of Preventing Industrial Water Chiller Failure ...

May 13, 2021 Professional water chiller manufacturers believe that if enterprises want to have high-quality low-temperature environment, they need to carry out detailed maintenance for industrial water chillers on a regular basis, which can avoid all kinds of small failures of industrial water chillers, affect the normal operation of industrial water ...

As Winter Approaches Don't Skip Chiller Maintenance

Nov 30, 2017 Step 3: Ensure a Leak-Free Unit. Leaks can affect the operation of the system and release hazardous refrigerants. Step 4: Sustain Proper Water Treatment. Failure to perform chiller maintenance can also affect water quality. It does not take much fouling or scale buildup to start impacting the efficiency of your system.

Industrial Chiller Water Filters Products Suppliers ...

Our air-cooled and water -cooled chillers are used in air coils, radiators, heat exchangers, nozzles, jacketed vessels, barrels, as well as mixers. Process Water Chillers Cooling Options. Compressor Motor Horsepower: 0.2500 to 5 HP. Condenser Cooling System: Air-Cooled, Water -Cooled. Cooling Capacity: 0.8792 to 106 kW.

Our Chiller Preventive Maintenance Services AG Services

Our industrial chiller maintenance services offer reduced operating costs and assure prevention from unexpected downtime in case of an equipment breakdown. Improve and Maintain Your Chiller’s Performance. ... We also ensure that it has excellent water quality and proper flow rates. We’ll check your control systems to ensure they keep your ...

Air-cooled Chiller vs. Water-cooled Chiller Comparison ...

Sep 10, 2019 Also, after factoring in chiller maintenance expenses like water quality testing, ... The planned location of a chiller unit is another important point to consider when deciding on the choice of an industrial chiller. Depending on site plans, there are pros and cons to opting for either air-cooled or water-cooled chillers. ...

Chiller Maintenance and Cleaning by the Experts - Part 2 ...

Sep 25, 2015 Treat condensor water to prevent scale and corrosion. Also, use remote monitoring to inspect your chilled water loops (whether annually or more often), to check general water quality, and to check for corrosion. Lower entering water temperature. This increases the unit’s efficiency. Keep chilled water flow rate between 3 to 12-ft per second ...

The Importance Of Chiller Maintenance -

The most basic work in the maintenance of the industrial chiller is to actually record the operating parameters of the unit at appropriate intervals (for example, ... Customers should perform water quality treatment in accordance with the requirements of GB50050-1995 Code for Design of Industrial Circulating Cooling Water Treatment. When the ...

Process Cooling Chillers - Atlas Copco USA

The TCX series is the first process cooling chiller range in the United States and is a compact, all-in-one water chiller with an air-cooled condenser and integrated hydro module. The TCX chillers are specially designed for cooling water (or a mixture of water and glycol) for a wide range of industrial processes, including: Food and beverage.

Effective Tips on the Way to Care and Maintain Industrial ...

The water quality should be well monitored to ensure proper chilling and heat transfer. Decrease entering water temperature. Decreasing the temperature of the entering water increases chiller efficiency. Keeping the chilled water flow between 3 to 12 feet per second ensures better efficiency. Maintain proper level of refrigerant

Installation Operation and Maintenance Manual

This equipment is not to be used as an industrial water source for drinking water for humans or animals. This chiller is designed to operate with a 50/50 water/propylene glycol mixture. Operation with plain water will lead to corrosion of the evaporator, and not safeguard the chiller from freezing in ambient temperatures below 32 F (0 C).

Industrial Water Chiller/System/Unit Manufacturer and ...

TopChiller can design and manufacture all types of industrial water chillers for you. TopChiller. Cooling capacity ranges from 5 Ton to 200 Ton. Temperature control ranges -25C to 25C. Famous brand Scroll screw compressor. Stainless steel reliable water pump and tank. Job-specific evaporator hot gas bypass.

Water-Cooled Chillers - York

YK Centrifugal Chiller. 250-3,000 TR (880-10,550 kW) Designed for maximum efficiency in the face of real-world variables, where 99% of the cooling season is spent in off-design conditions. With the OptiSpeed™ Drive, energy consumption can be as low as .20 kW/TR, reducing annual energy costs by as much as 30%.

Water Cooled Chiller Manufacturer and Supplier in China ...

Yushine is a professional manufacturer and supplier of Water Cooled Chiller with over 15 years of experience. 18-month warranty, Lifelong maintenance, and any feedback will respond in 24 hours. Yushine water-cooled chiller should be 100% trial run and follow the quality control system strictly. Send us your requirement, we will offer you a ...

Contact Us
advanced technology

High-tech Zone, Zhengzhou, China

Inquiry Online
Related Post
Leave Us Message
customer service img

We immediately communicate with you

Get Quote Online

If you have any needs or questions, please click on the consultation or leave a message, we will reply to you as soon as we receive it!

<script type="text/javascript" src="https://v1.cnzz.com/z_stat.php?id=1281099841&web_id=1281099841"></script>