Get a Quote

Instruction Manual - For All Hot Plates Stirrers and ...

4 Heat Control Knob: Turn it all the way counterclockwise to turn off heating function. Turn it clockwise to set desired heating temperature. 5 Heating Temperature Display: Shows the temperature set for heating. 6 Hot Top Indicator: Illuminates when the temperature of the top is too hot to touch (greater than ~60C).

Power usage of heating mantle. Download Table

According to the JP Selecta Laboratory Equipment Manufacturer, heating mantles can use between 130 W and 2300 W of power to heat a reaction flask ( Table 1) (6). The amount of electricity needed ...

HACCP-Based Standard Operating Procedures (SOPs)

appropriate temperature by placing a piece of heat sensitive tape on a smallware item or a maximum registering thermometer on a rack and running the item or rack through the dishmachine. • For chemical sanitizing dishmachine, check the sanitizer concentration on a recently washed food- ... HACCP-Based Standard Operating Procedures (SOPs) ...

SOP on Good Laboratory Practices (GLP) - Pharmaceutical ...

Apr 09, 2016 Also add glass beads to avoid bumping and for constant heating. Place the distillation flask on the heating mantle and connect it to the condenser through a connector tightly. Place the receiving vessel near the tip of the condenser. Check the water connections and start it. Set the temperature of the heating mantle and start the heating.

SOP 13 - Ohio State University

Aug 21, 1995 Heating with dry oxygen or a dry inert gas at a flow rate of about 3 SCFH (standard cubic feet / hr) is continued for at least 4 to 5 hours. VII.4. Cooling Flask Down to Room Temperature in Heating Mantle. At the end of the heating period, the variac is turned off (or when possible, gradually turned down from 50 to 0 over about an hour).

Standard Operating Procedure (SOP)

Centrifugation SOP template 7 Revised: 06/2019 MTD 6. Step-by-Step Operating Procedure Provide the steps required to perform this procedure. For a process: Write enough detailed description of the procedure to guide the user through the process including details of startup, normal condition operation, temporary operation condition, and emergency

Mini Pressure Reactor Standard Operating Procedure

Check that the stirrer is on, and set the reaction temperature, high temperature shutdown (25 C above reaction temperature), and heating mantle overtemperature (100 C above reaction temperature). Slide the heating mantle onto the reactor vessel and tighten the screw clamp. Flip the heater switch on the front of the control tower to begin ...

Safety Operating Procedures - Oven

Do not heat a sealed container. Do not heat any flammable or combustible liquid in the oven. A fire and/or explosion may result. Do not heat any material that might pose a hazard because of acute or chronic toxicity, unless special precautions have been taken to ensure continuous venting of the atmosphere inside the oven. Do not overheat the ...

SOP STANDARD OPERATING PROCEDURE - UNE

heating adjust air inlet/gas to stable heating flame that won’t self-extinguish. 11. Do not leave a Bunsen burner lit and unattended, even for a short period. 12. Double check the gas outlet is properly closed and the Bunsen flame extinguished before leaving the lab. 13. Label any equipment with residual heat which is to be left unattended

Heating Mantle Sop Pdf

Heating Bath SOP 2013 1 Standard Operating Procedure Heat Sources and Heating Baths 1. Procedure/Hazardous Material: Includes, but not limited to ovens, hot plates, heating mantles and tapes, oil baths, salt baths, sand baths, hot-air guns, and microwave ovens. 2. Department: Campus wide 3. Revision Date: February 2013 4. Special Notifications:

Heating Basic laboratory procedures II Fundamental ...

Heating control is provided either by a regulator built into the heating mantle (Fig. 5.13a) or by an external controller, which is connected to the mantle by a plug. Some mantles, 'stirrer mantles', have a built-in magnetic stirrer just like a stirrer hot plate and can be used to mix the liquid using a magnetic flea or bar (Fig. 5.13b).

Heating Mantle (Digital Magnetic) - Toolots

Heating Mantle . 98-II-B Magnetic Heating Mantle. 98-I-C / 98-II-C Digital Heating Mantle ... Users should read this Manual carefully, follow the instructions and procedures, and beware of all the cautions when using this instrument. ... Operating Modes. 5.1 98-I-B Manual Heating Mantle and 98-IV-B Rows Manual Heating . Mantle:

Standard Operating Procedure - Rotary Evaporator

hot bath. Since water is typically present in the hot bath, the heating system will not heat above 100 degrees. 14. If you have not already turned on the rotary evaporator, press the power button on the rotary evaporator control panel. 15. Use the dial on the rotary evaporator control panel to set the desired spin speed of the condenser. 16.

How To Operate Heating Mantle Lab Heating Apparatus

hydrothermal synthesis reactor together, you also could use it to heating liquid separately. 1. Connect 220V power source, turn on power source switch. Interface will display K, settings window will display 400, K type thermocouple is equipped with this heating mantle, max controlled temperature is 400℃. After 3s, dispaly window.

A Step-by-Step Guide to Writing SOPs for Business - Blissfully

Nov 17, 2021 4. Specify the SOP structure. If your company is small, or if you’re a startup, you can keep things more informal. Just make sure that whatever structure you choose will work for the whole team. Once you start expanding, however, you might have to decide on a more formal structure, like a flowchart.

Standard Operating Procedure: Used Oil Disposal

procedure is to describe the proper means for handling and disposing of used oil from equipment maintenance operations, process procedures, and any other activities where used oils are generated. 2.0 Scope . This procedure applies to the disposal of any oil that is collected during used normal work functions at UVA. Used oil may include: 1.

SOP 15 - Ohio State University

Purification and recovery of organic solvents by distillation is a common laboratory operation. Instructions and descriptions for the distillations of hexanes, tetrahydrofuran (THF), diethyl ether, dimethoxyethane, benzene, toluene and dichloromethane are included in this SOP. II. ... temperature control of the heating mantle and contents (burn ...

Safe Operating Procedure

Safe Operating Procedure (10/15) ASBESTOS FACTS _____ Scope . This SOP is intended to provide general awareness information to the campus community on the presence and hazards of asbestos-containing materials. What is asbestos? ... heating mantles, ovens, and electric motors. Height of production and use occurred from the 1940s through the ...

SOP - High Temperature Box Furnace Safety Web Oregon ...

STANDARD OPERATING PROCEDURE: High Temperature Box Furnace Oregon State University, Department of ChemistryStandard Operating Procedure (SOP): Safe Use of High Temperature Box Furnaces (ver. 1.0)Author: Mas Subramanian ([email protected])Safety Web Inception Date: 3/01/2010Revised: N/A …

STANDARD OPERATING PROCEDURES - WTAMU

STANDARD OPERATING PROCEDURES SOP No. 24.01.01.W1.22AR Chemical Safety Procedure Approved: August 15, 2010 ... oil bath, heating mantle, hot air bath, etc. Use ground straps when transferring flammable chemicals between metal containers to avoid generating static sparks. Use a fume hood when there is a possibility of dangerous vapors ...

Procedures - University of California Davis

STANDARD OPERATING PROCEDURES. revised July 2006. SOLVENT STILLS 2. ROTARY EVAPORATOR 6. INERT ATMOSPHERE GLOVE BOX 8. FUME HOODS 12. Ultra-Sonicator 13. ... Each still consists of a heating mantle, heating mantle controller, 2 litre round bottom flask (24/40 female joint), still head, condenser, and nitrogen/argon adapter. ...

Electrical Equipment Safety Procedures

stirrer/heater, heat gun, heating mantle, etc • Movable: an appliance that can be moved readily from one place to another by unplugging from a general purpose outlet, but that is not moved during operation. Examples: cathode ray oscilloscope, electronic balance, personal computer, printer, portable power generating equipment, etc

Standard Operating Procedures of Hand Tools

The head is made of heat treated forged high carbon steel that is harder than a claw hammer. The round “peening” end is used less in metalworking than it used to be, but it is meant to work and shape malleable metals. Do: Wear safety glasses Hold onto the rubber grip with your dominant hand Place your work piece on a hard surface

How to set up a reflux apparatus

The heating mantle should fit the flask size. The temperature will be difficult to control if the heating mantle lacks contact with the flask. The heating mantle will overheat or burn out if left unintended for too long. • Add the sand into the heating mantle. Make sure the sand occupies 2/3 of the heating mantle. Figure 1 Reflux Apparatus

SOP for Safety In Quality Control Laboratory ...

The purpose of this SOP is to lay down a procedure to describe safety rules and precautions during working in the Quality Control department. ... Use a water-bath or electric heating mantle when large amounts of flammable solvents are to be …

Standard Operating Procedure

the SDS, container or a Standard Operating Procedure (SOP). AVOIDANCE OF ROUTINE EXPOSURE Develop and encourage safe habits. Avoid unnecessary exposure to chemicals by any route. ... • Provide fail-safe provisions for equipment such as power stirrers, hot plates, heating mantles and water condensers.

Heating Mantle Multi Position

These heating mantle, multi position are designed to heat between 3 and 6 round bottom flasks simultaneously. They are often used for distillation, extraction and reflux procedures, wherever heating of multiple flasks is required.Each heating mantle can be regulated with its individual built-in temperature controller.Maximum operating temperature of heating elements is …

Standard Operating Procedure - Yale University

This standard operating procedure (SOP) is intended to provide general guidance on how to safely work with flammable liquids. ... • Never heat flammable liquids by using an open flame. Use steam baths, water baths, oils baths, heating mantles or hot air baths. • If flammable liquids must be heated in an oven, make sure the oven is ...

Techno Heat MantleA - Summit Research

This Techno-heat mantle and controller adopt the touch screen with high technology which makes easy to monitor the operation of heating mantle. Furthermore, this Techno -heat mantle set contains 3 kinds of interfaces; it’s capable to store the testing data in USB storage and it can be remote-controlled by smart phone wherever you’re in.

Contact Us
advanced technology

High-tech Zone, Zhengzhou, China

Inquiry Online
Related Post
Leave Us Message
customer service img

We immediately communicate with you

Get Quote Online

If you have any needs or questions, please click on the consultation or leave a message, we will reply to you as soon as we receive it!

<script type="text/javascript" src="https://v1.cnzz.com/z_stat.php?id=1281099841&web_id=1281099841"></script>